Title: Selective, nanomolar electrochemical determination of environmental contaminants dihydroxybenzene isomers found in water Bodies using nanocrystalline zeolite modified carbon paste electrodes
Authors: Kaur, B.
Srivastava, R.
Keywords: Dihydroxybenzene isomers
Electrocatalytic oxidation
Nanocrystalline zeolites
Simultaneous determination ·
contaminants
Issue Date: 27-Sep-2021
Abstract: Nanocrystalline zeolites of different framework structures were prepared by the addition of suitable structure directing agents in the synthesis composition of conventional zeolites. Zeolite modified carbon paste electrodes were constructed for the simultaneous determination of dihydroxybenzene isomers. Nanocrystalline zeolite Beta modified carbon paste electrode exhibited the highest electrocatalytic activity. Under optimum conditions, wide linear range was obtained from 150 nM to 400 mM with lower detection limit of 100, 130, and 100 nM for hydroquinone, catechol, and resorcinol, respectively. The analytical performance of the proposed sensor was demonstrated in the simultaneous determination of dihydroxybenzene isomers in different environmental water samples.