Please use this identifier to cite or link to this item: http://dspace.iitrpr.ac.in:8080/xmlui/handle/123456789/3215
Title: X-Ray diffraction study of cold sprayed Ni-20Cr and Ni-50Cr coatings on boiler
Authors: Bala, N.
Singh, H.
Prakash, S.
Keywords: X-ray Diffraction
residual stresses
cold spray coatings
hot corrosion
Issue Date: 22-Nov-2021
Abstract: X-ray diffraction (XRD) is a versatile, non-destructive technique that reveals detailed information about the chemical composition and crystallographic structure of materials. In this work Ni-20Cr and Ni-50Cr coatings were deposited on two boiler steels namely T22 and SA 516 steel. The measurement of residual stresses of these cold sprayed coatings was done with the help of X-ray diffraction technique. This paper discussed the XRD study of the as-sprayed coatings. Further the XRD technique was used to study the uncoated and coated steels after cyclic exposure to air, molten salt [Na2SO4-60%V2O5], and actual boiler environments. The results obtained from the XRD analysis have been shown. The weight change results showed that the coated steels performed better than their uncoated counterparts which might be attributed to the formation of protective phases
URI: http://localhost:8080/xmlui/handle/123456789/3215
Appears in Collections:Year-2013

Files in This Item:
File Description SizeFormat 
Full Text.pdf330.39 kBAdobe PDFView/Open    Request a copy