Title: | Floor displacement-based torsional amplification factors for seismic design of acceleration-sensitive non-structural components in torsionally irregular RC buildings |
Authors: | Jain, A. Surana, M. |
Keywords: | Floor response spectra Moment-resisting frame Non-structural component Torsional amplification Torsional irregularity |
Issue Date: | 5-May-2022 |
Abstract: | In this study, the effects of inherent building torsion on the seismic response of acceleration-sensitive non-structural components are investigated. To achieve this objective, a group of elastic torsionally irregular step-back reinforced concrete moment-resisting frame buildings are analyzed under bi-directional earthquake excitations. The floor torsional amplification factors, defined as the ratio between the floor spectral ordinate at the flexible/stiff edge to the floor spectral ordinate at the center of rigidity, are obtained as a function of the tuning ratio for varying damping ratios of non-structural components. The correlations of the peak torsional amplification factors at different floors for the rigid and flexible non-structural components are studied with their floor displacement-based torsional irregularity indices, recommended in the national building codes of the United States and India. It is observed that the torsional amplification factors are building characteristics and tuning ratio-dependent. These torsional amplification factors are further observed to be well-correlated with the corresponding floor displacement-based torsional irregularity indices for both the rigid and flexible non-structural components. Contrarily, the torsional amplification factors for the very flexible non-structural components tend to unity and are thereby observed to be independent of the characteristics of both the building and the non-structural components. Simplified and numerically validated, floor displacement-based models are proposed to compute the torsional amplification factors, which can be used in aggregation with the existing codes to design acceleration-sensitive non-structural components in torsionally irregular buildings. |
URI: | http://localhost:8080/xmlui/handle/123456789/3399 |
Appears in Collections: | Year-2022 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Full Text.pdf | 10.36 MB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.