Please use this identifier to cite or link to this item: http://dspace.iitrpr.ac.in:8080/xmlui/handle/123456789/4407
Title: Comparative analysis of residual pressure drop behavior between electrostatically assisted flat based and pilot pulse jet filter unit using conductive filter media
Authors: Dutta, S.
Mukhopadhyay, A.
Choudhary, A.K.
Reddy, C C.
Keywords: Conductive filter media
Correlation behavior
Dust charge
Dust concentration
Residual pressure drop
Issue Date: 5-May-2024
Abstract: The present study aims at comparing the pressure drop behavior of three different needle-punched polyester conductive materials, viz. PTFE coated media, stainless steel fibre blended with PET media and stainless steel fibre scrim media. This comparison is done on a laboratory-based electrostatically assisted pulse-jet flat media test rig with the pilot filter unit, which is closer to the industrial set-up. The materials are investigated using fly ash aerosol, pre-charged at three different levels of charge, viz. 4 kV, 8 kV and 12 kV. The interpretations reveal that the flat media test rig is observed to exhibit lower residual pressure drop for all the investigated materials.
URI: http://dspace.iitrpr.ac.in:8080/xmlui/handle/123456789/4407
Appears in Collections:Year-2023

Files in This Item:
File Description SizeFormat 
full text.pdf1.38 MBAdobe PDFView/Open    Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.