Please use this identifier to cite or link to this item: http://dspace.iitrpr.ac.in:8080/xmlui/handle/123456789/736
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBala, N.-
dc.contributor.authorSingh, H.-
dc.contributor.authorPrakash, S.-
dc.contributor.authorKarthikeyan, J.-
dc.date.accessioned2016-12-02T10:14:01Z-
dc.date.available2016-12-02T10:14:01Z-
dc.date.issued2016-12-02-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/736-
dc.description.abstractHigh temperature corrosion accompanied by erosion is a severe problem, which may result in premature failure of the boiler tubes. One countermeasure to overcome this problem is the use of thermal spray protective coatings. In the current investigation high velocity oxy-fuel (HVOF) and cold spray processes have been used to deposit commercial Ni-20Cr powder on T22 boiler steel. To evaluate the performance of the coatings in actual conditions the bare as well as the coated steels were subjected to cyclic exposures, in the superheater zone of a coal fired boiler for 15 cycles. The weight change and thickness loss data were used to establish kinetics of the erosion-corrosion. X-ray diffraction, surface and cross-sectional field emission scanning electron microscope/energy dispersive spectroscopy (FE-SEM/EDS) and x-ray mapping techniques were used to analyse the as-sprayed and corroded specimens. The HVOF sprayed coating performed better than its cold sprayed counterpart in actual boiler environment.en_US
dc.language.isoen_USen_US
dc.subjectCold sprayen_US
dc.subjectErosion-corrosionen_US
dc.subjectHVOFen_US
dc.titleInvestigations on the behavior of hvof and cold sprayed Ni-20Cr coating on T22 boiler steel in actual boiler environmenten_US
dc.typeArticleen_US
Appears in Collections:Year-2012