Title: | An improved constrained inverse optimization method for mechanical draft cooling towers |
Authors: | Singh, K. Das, R. |
Keywords: | Constrained optimization method Optimum operating parameters Power saving ALGA Feedback and control |
Issue Date: | 13-Jun-2017 |
Abstract: | In this work, a constrained multiple parameter inverse identification technique is proposed for a mechanical cooling tower to meet a required heat rejection rate from hot water and also ensuring minimum power consumption. The present technique minimizes the relevant objective function involving the total tower power consumption satisfying the constraint of the required heat load in the inverse analysis. The constraint uses a continuous polynomial function obtained using the experimental data with mass flow rate of air and water as control variables. The comparison of the present constrained inverse retrieval technique is made against the traditional unconstrained inverse parameter retrieval technique satisfying the same heat load. The demonstration of the constrained and the unconstrained inverse retrieval techniques as live feedback tool controlling the tower performance is also presented. The proposed constrained inverse parameter retrieval-based feedback technique is found preferable to ensure least power consumption meeting a required tower heat load. |
URI: | http://localhost:8080/xmlui/handle/123456789/835 |
Appears in Collections: | Year-2017 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Full Text 1.pdf | 51.02 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.