INSTITUTIONAL DIGITAL REPOSITORY

Effects of various loading on the performance of MEMS cantilever beam for in-field tuning of sensors and actuators for high temperature and harsh environment applications

Show simple item record

dc.contributor.author Dounkal, M.K.
dc.contributor.author Bhan, R.K.
dc.contributor.author Kumar, N.
dc.date.accessioned 2020-03-11T09:28:32Z
dc.date.available 2020-03-11T09:28:32Z
dc.date.issued 2020-03-11
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/1513
dc.description.abstract MEMS devices require active mechanism for tuning in field operation because post fabrication, design parameters may change due to residual stress, fabrication imperfections, temperature etc. Application of axial compressive (C) or tensile forces (T) allows one to implement this tuning. Effects of C and T forces, stress gradient (SG) and transverse loading is analyzed for futuristic materials like Gallium Nitride (GaN) and Silicon Carbide (SiC) for use in high temperatures and harsh environments. The effects of above forces on pull in voltage (VPI), bandwidth (BW) and resonance frequency (RF) are analyzed. Results for Aluminum cantilever beam show, that VPI decreases by * 1.2 times at low beam lengths of 200 lm and about 5 times at higher length of 800 lm when T force is changed to C under loading. Similar trends are holding for GaN and SiC except that VPI scales up in proportion to material’s Young’s modulus E. An analytical relations of VPI versus E and Poisson’s ratio‘m’ are predicted. Effect of SG is also studied and it is found that although SG affects VPI within 10% range, application of axial C or T forces further change it within 20% range. Comparison of analytical results for VPI with Coventorware software shows a better agreement for low loading of 10% compared to full loading of 100%. Also, Log–Log plot of VPI versus L can be used to estimate the contribution of charge re-distribution and fringing field. Furthermore, BW decreases by 16 Hz when C is applied and increases by 66 Hz when T is applied for Aluminum cantilever with 400 lm length and 50 lm width. Similarly, RF decreases by 165 Hz in C and increases by 623 Hz for T loading. The predictions of our model agree well with experimental and FEM results (within 4.54% and 6.46% respectively). en_US
dc.language.iso en_US en_US
dc.title Effects of various loading on the performance of MEMS cantilever beam for in-field tuning of sensors and actuators for high temperature and harsh environment applications en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account