| dc.contributor.author | Kumar, M. | |
| dc.contributor.author | Jayaraman, K. | |
| dc.date.accessioned | 2021-06-17T20:50:47Z | |
| dc.date.available | 2021-06-17T20:50:47Z | |
| dc.date.issued | 2021-06-18 | |
| dc.identifier.uri | http://localhost:8080/xmlui/handle/123456789/1841 | |
| dc.description.abstract | This paper presents an impedance shaping technique to reshape the common mode (CM) impedance profile of three phase common mode choke. The CM impedance offered by a designed CM choke with specific core area and number of turns is reshaped using CMIS choke. CM noise in a two level voltage source inverter (TL-VSI) has dominant frequency components near inverter switching frequency (Fsw). Attenuation of these dominant frequency components demand high impedance at Fsw. A designed CMIS choke offers high CM impedance for Fsw compared to CCM choke. The proposed three phase CMIS choke is a passive CM noise attenuation technique that attenuates the dominant Fsw components. The CM attenuation performance of passive EMI filter with CMIS choke and CCM choke are compared for TL-VSI. | en_US |
| dc.language.iso | en_US | en_US |
| dc.subject | Common mode noise | en_US |
| dc.subject | conventional common mode choke | en_US |
| dc.subject | common mode impedance shaping choke | en_US |
| dc.subject | electromagnetic interference | en_US |
| dc.subject | two level voltage source inverter | en_US |
| dc.title | Common mode impedance shaping choke to attenuate the conducted EMI in three phase drive | en_US |
| dc.type | Article | en_US |