INSTITUTIONAL DIGITAL REPOSITORY

Self-reliant feature in DC-DC converters for open circuit faults

Show simple item record

dc.contributor.author Bhakar, P. S.
dc.contributor.author Kalaiselvi, J.
dc.date.accessioned 2021-06-17T21:04:25Z
dc.date.available 2021-06-17T21:04:25Z
dc.date.issued 2021-06-18
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/1843
dc.description.abstract With vast applications of dc-dc converters in grids and micro grids, the need of a vigorous converter with fault tolerant capability becomes very important. Dual active bridge (DAB) and series resonant converters (SRC) are extensively used in smart transformers. Hence the fault tolerant feature is a must in such converters in order to maintain a continuous operation with voltage and power regulation. This paper proposes the analysis of single or two switch open circuit fault on primary and secondary side of DAB and SRC. The self-reliant nature of converter in achieving fault tolerance with the help of phase shift between its input and output side is also discussed. The proposed analysis is tested on 1kW, 250V DAB and SRC prototype. The proposed correction for open circuit fault on SRC is simulated in PLECS software. en_US
dc.language.iso en_US en_US
dc.subject Self-reliant en_US
dc.subject fault tolerant en_US
dc.subject Open circuit faults en_US
dc.subject dual active bridge converter en_US
dc.subject series resonant converter en_US
dc.title Self-reliant feature in DC-DC converters for open circuit faults en_US
dc.type Article en_US