INSTITUTIONAL DIGITAL REPOSITORY

Thermal design of a humidification-dehumidification desalination cycle consisting of packed-bed humidifier and finned-tube dehumidifier

Show simple item record

dc.contributor.author Garg, K.
dc.contributor.author Das, S. K.
dc.contributor.author Tyagi, H.
dc.date.accessioned 2021-12-19T09:54:54Z
dc.date.available 2021-12-19T09:54:54Z
dc.date.issued 2021-12-19
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/3322
dc.description.abstract Humidification-dehumidification (HDH) desalination technology is an ideal technology for off-grid and remote locations where fresh water requirement is approximately between 1-100 m3/day. The principal components of the HDH system such as humidifier and dehumidifier have already been utilized in various industrial applications for some time and are readily available in the market. But the actual thermal performance of the HDH system depends on the specific type and size of the components used. In the present study, a detailed heat and mass transfer model has been prepared for a closed-air openwater (CAOW) and water-heated type HDH cycle which uses a counter-flow packed-bed cooling tower for humidification of air and finned-tube heat exchanger for dehumidification purpose. With the help of transport model, the optimum sizes of the humidifier and dehumidifier have been obtained for a desired thermal performance of the cycle, measured in terms of gained output ratio (GOR) and recovery ratio (RR). Additionally, a very basic thermodynamic model for the same HDH cycle is also prepared in order to validate the results of the transport model and results from both the models are found to be in close agreement with each other. Parametric study reveals that for fixed sizes of the humidifier and dehumidifier, there always exists an optimum value of mass flow rate ratio, top brine temperature and feed water temperature at which the GOR of the cycle is maximum. It is also concluded that the thermal performance of the system is greatly influenced by the performance of the dehumidifier as compared to the performance of the humidifier. Finally, the present work will be helpful to design a similar HDH system as per the required GOR and RR. en_US
dc.language.iso en_US en_US
dc.subject Desalination en_US
dc.subject Humidification-dehumidification en_US
dc.subject Packed-bed humidifier en_US
dc.subject Finned-tube heat exchanger en_US
dc.title Thermal design of a humidification-dehumidification desalination cycle consisting of packed-bed humidifier and finned-tube dehumidifier en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account