dc.description.abstract Space charge measurement in dielectric materials is very important to understand breakdown mechanism in power cables. Among several methods like pulsed electro-acoustic method, pulse propagation method, laser induced pressure propagation, the pulsed electro-acoustic method is widely used for space charge measurement due to ease of application. However, the signal obtained in the method does not represent original space charge. To obtain original space charge signal de-convolution is required. In this paper, authors examined applicability of sparse de-convolution to obtain original space charge signal using the pulsed electro-acoustic method. Charge signal obtained using poly methyl methacrylate sample, in authors' laboratory has been taken as a reference. en_US
dc.language.iso en_US en_US
dc.subject Acoustic signal en_US
dc.subject Breakdown en_US
dc.subject Insulation en_US
dc.subject Power cable en_US
dc.subject Pulsed electro acoustic method en_US
dc.subject Space charge en_US
dc.subject Sparse de-convolution en_US
dc.title Sparse de-convolution of space charge signal in PEA method en_US